Nominal voltage | |
---|---|
Specific value | 24 VDC |
Limit values, min/max | 10/30 VDC |
Nominal current, typically | |
Specific value | 40 mA |
Condition | unloaded |
Supply | |
SELV/PELV | IEC 60364-4-41 |
In case of UL / CSA approval | according to NEC Class 2 |
Signal form | SIN/COS |
Signal form, alternative | Square |
Incremental signals, square | |
Channels | K1+, K1-, K2+, K2- |
Phase position, electrically | 90 ° |
Zero pulse, square | |
Channel (Channels) | K0+, K0- |
Number of revolutions | 1x |
Incremental signals, SIN/COS | SIN± COS±, 1 Vss |
Output frequency | <= 500 kHz |
Load current | <= 20 mA |
Zero pulse, SIN/COS | |
Channel (Channels) | Ref+, Ref- |
Impulses, square wave | 1024 |
2048 | |
4096 | |
Impulses, SIN/COS | 1024 |
2048 | |
4096 | |
Accuracy | |
Applicable resolution | 10 Bit, 11 Bit, 12 Bit |
Safety-related | + 2 Bit interpolated |
Functional | + 8 Bit interpolated |
Output stages | |
Factory setting | TTL / HTL |
Output driver, TTL | |
Output level | RS-422, 5 VDC |
Load current | <= 50 mA |
Load current | per Channel |
Output frequency | <= 100 kHz |
Short-circuit proof | yes |
Output driver, HTL | |
Short-circuit proof | yes |
Output level | Push-Pull, supply voltage |
Load current | <= 50 mA |
Load current | per Channel |
Output frequency | <= 100 kHz |
Speed, electrically [1/min] | (f-Cutoff/Imp. Rev) * 60 1/min |
Parameter/Function, changeable | Number of pulses |
Output stage (TTL/HTL) | |
Type of parametrization | Factory setting |
Functional safety | |
SIL-Standardization | DIN EN 61508 / DIN EN 62061 |
SIL-Standardization | DIN EN 61800-5-2 |
SIL-Level | SIL2 / SIL CL 2 |
SIL-Level | SIL3 / SIL CL 3 |
PL-Standardization | DIN EN ISO 13849-1 |
Performance-Level (PL) | PLe / Cat. 3 |
Performance-Level (PL) | PLd / Cat. 3 |
Service life | 20 Years |
PFH | 5.34E-9 1/h (SIN/COS) |
PFH | 6.57E-9 1/h (TTL/HTL) |
MTTFd |