General specifications | |
|---|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Output type | 2-wire |
Nominal ratings | |
| Nominal voltage | 8.2 V (Ri approx. 1 k?) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Switching state indicator | LED, yellow |
Compliance with standards and directives | |
| Standard conformity | |
Ambient conditions | |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications | |
| Connection type | cable PUR , black 30 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Degree of protection | IP67 |