Technical data | EQ3314-0002 |
---|
Number of inputs | 4 |
Housing width in mm | 39 |
Connection method | screw type M12, 2-wire connection for thermocouple |
Protocol | EtherCAT |
Bus interface | 2 x M8 socket, shielded, screw type |
Sensor types | types J, K, L, B, E, N, R, S, T, U (default setting type K), mV measurement |
Signal type | thermocouple |
Measuring range | depending on sensor type; preset value is type K, -100…+1370 °C |
Resolution | 0.1 °C per digit |
Measuring error | < ±0.3="" %="" for="" type="" k="" (relative="" to="" full="" scale="" value;="" further="" types="" see=""> |
Conversion time | 2.5 s up to 20 ms, see documentation, default: approx. 250 ms |
Distributed clocks | – |
Input filter | 5 variations, configurable |
Current consumption from US | 120 mA |
Power supply connection | feed: 1 x M8 male socket, 4-pin; downstream connection: 1 x M8 female socket, 4-pin |
Bit width in the process image | 4 x 32 Или отправьте нам запрос на output |
Electrical isolation | 500 V |
Special features | V2A stainless steel, Hygienic Design |
Dimensions (W x H x D) | 39 mm x 160 mm x 43 mm |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. class/installation pos. | IP 69K (according to EN 60529)/variable |
Approvals | CE, UL |