Technical data | EP3744-0041 |
---|
Number of channels | 6 digital inputs, 2 digital outputs, 4 pressure inputs |
Connection method | digital signals: 4-pin M8; pressure measurement: 6 mm fitting |
Protocol | EtherCAT |
Signal type | air pressure |
Measuring range | 0…1 bar (0…15 psi)/-1…1 bar (-15…15 psi) |
Resolution | 1 mbar per digit |
Measuring error | 3 % |
Conversion time | ~ 3.5 ms |
Nominal voltage | 24 V DC (-15 %/+20 %) |
Distributed clocks | yes |
Input filter | 10 µs (for digital inputs) |
Specification | EN 61131-2, type 1/3 |
Max. output current | 0.5 A per channel, individually short-circuit-proof |
Load type | ohmic, inductive, lamp load |
Short circuit current | typ. 1.5 A |
Sensor supply | from load supply voltage, max. 0.5 A total, short-circuit-proof |
Current consumption from US | 120 mA |
Power supply connection | feed: 1 x M8 male socket, 4-pin; downstream connection: 1 x M8 female socket, 4-pin |
Electrical isolation | 500 V |
Special features | direct pressure measuring at the machine |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. class/installation pos. | IP 65/66/67 (conforms to EN 60529)/variable |
Approvals | CE, UL |