Technical data | ELM3604-0002 |
---|
Number of channels | 4 |
Technology | IEPE, voltage measurement |
Signal type | single-ended |
Connection technology | 2-wire |
Connection type | BNC, shielded |
Max. sampling rate | max. 50 µs/20 ksps (per channel, simultaneously) |
Oversampling factor | n = 1…100 selectable |
Internal resistance | > 2 MΩ |
Measuring error | typ. ±100 ppm/±0.01 % relative to the respective full scale value (DC) @ 23 °C |
Temperature coefficient | typ. < 10=""> |
Functional diagnostics | yes |
Connection diagnostics | broken wire/short-circuit |
Distributed clocks | yes, accuracy < 1=""> |
Current consumption power contacts | – |
Current consumption E-bus | typ. 460 mA |
Weight | approx. 350 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Thermal dissipation | typ. 3 W |
Special features | ExtendedRange 107 %, free numeric filter, TrueRMS, integrator/differentiator, non-linear scaling, PeakHold |
Approvals/markings | CE, UL |