Technical data | ELM3502-0000 |
---|
Number of channels | 2 |
Technology | resistor bridge, strain gauge |
Signal type | differential |
Connection technology | 2-/3-/4-/5-/6-wire |
Connection type | push-in, service plug 6-pin |
Max. sampling rate | max. 50 µs/20 ksps (per channel, simultaneously) |
Oversampling factor | n = 1…100 selectable (max. 20 ksamples/s) |
Internal resistance | > 4 MΩ |
Measuring error | up to typ. ±500 ppm/0.05 % relative to the respective full scale value |
Temperature coefficient | up to < 10="" ppm/k=""> |
Functional diagnostics | yes |
Connection diagnostics | broken wire/short-circuit |
Distributed clocks | yes, accuracy < 1=""> |
Current consumption power contacts | – |
Current consumption E-bus | typ. 450 mA |
Weight | approx. 350 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Thermal dissipation | typ. 3 W |
Special features | ExtendedRange 107 %, free numeric filter, TrueRMS, integrator/differentiator, non-linear scaling, PeakHold |
Approvals/markings | CE, UL |