Mechanical values and environment | |
---|---|
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | |
1 x 106 | |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation position | Door hinge DIN left |
Reaction time | |
Emergency stop / machine stop | Switch-off timemax.250 ms The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol. |
Door position | Switch-off timemax.550 ms The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol. |
Bolt position | Switch-off timemax.550 ms The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol. |
Guard locking | Switch-off timemax.550 ms The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol. |
Switching frequency | 0,25 Hz |
Connection | |
Push-pull power X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.) | |
Push-pull power X2 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.) | |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 X3 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.) |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.) |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings | |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Unicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% (Reverse polarity protected, regulated, residual ripple <5%,> |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% The auxiliary voltage is not required for the MGB system |
Fusing | |
external | Slow blowmin.1 A |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% For looping through for connected devices |