General specifications | |
---|---|
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 40 mm |
Installation | non-flush |
Output polarity | DC |
Assured operating distance | 0 ... 32.4 mm |
Actual operating distance | 36 ... 44 mm typ. 40 mm |
Reduction factor rAl | 0.31 |
Reduction factor rCu | 0.3 |
Reduction factor r304 | 0.74 |
Reduction factor rBrass | 0.39 |
Output type | 3-wire |
Nominal ratings | |
Operating voltage | 10 ... 30 V DC |
Switching frequency | 0 ... 150 Hz |
Hysteresis | typ. 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ? 2 V |
Voltage drop at IL | |
Operating current | 0 ... 200 mA |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
No-load supply current | ? 20 mA |
Time delay before availability | 80 ms |
Operating voltage indicator | LED, green |
Switching state indicator | LED, yellow |
Functional safety related parameters | |
MTTFd | 1358 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives | |
Standard conformity | |
Approvals and certificates | |
FM approval | hazardous (classified) location Non-incendive |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications | |
Connection type | screw terminals |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Core cross-section | up to 2.5 mm2 |
Housing material | PA |
Sensing face | PA |
Degree of protection | IP68 / IP69K |
Mass | 225 g |
Note | Tightening torque: 1.8 Nm (housing) |
Equipment protection level Gc (nA) | |
Certificate | PF 15CERT3754 X |
CE marking | [*PD-Z02586A*] |
ATEX marking | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. |
Standards | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category "n" Use is restricted to the following stated conditions |
Special conditions | |
Equipment protection level Dc (tc) | |
CE marking | [*PD-Z02586A*] |
ATEX m |