Регистрация
deal.by
Light grid LGM8 - фото 1 - id-p95194511
Характеристики и описание

Техническая спецификация в PDF  

Описание оборудования

Measuring automation light grid with beam spacing of 8 mm, IO-Link interface, push-pull output, fixed cable with M12 plug

General specifications

Effective detection rangeStandard : 0.3 ... 6 m
Threshold detection range7.5 m
Light sourceIRED
Light typemodulated infrared light , 850 nm
Field heightsee Table 1, max. 2100 mm
Beam crossoverFactory setting: three beam crossing, deactivateable
Beam blankingadjustable max. 2 fixed suppressible beam areas (blanking)
Beam spacing8.33 mm
Number of beamssee Table 1, max. 253
Operating modeEmitter: Emitter power adjustable in two ranges
Optical resolutionwithout beam crossover: 8 mm
with beam crossover: 4 mm with in 25% and 75% of the range
Angle of divergence10 °
Ambient light limit> 50000 Lux (if external light source is outside the opening angle)

Functional safety related parameters

MTTFd21 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)60 %

Indicators/operating means

Operation indicatorLED green:
constantly on - power-on
double pulse flashing (0.8 Hz) - undervoltage
flashing (4 Hz) - short circuit
flashing with short interruptions (1 Hz) - IO-Link mode
Status indicatorEmitter: LED yellow
constantly on - high emitter power
constantly off - low emitter power
flashing (8 Hz) - error message
Receiver: LED yellow:
constantly on - object detected
constantly off - no object detected
flashing (4 Hz) - below stability control limit
flashing (8 Hz) - error message
Control elementsReceiver: 2 touch buttons for programming

Electrical specifications

Operating voltage18 ... 30 V DC
Ripple10 %
No-load supply currentEmitter ?: 50 mA
Receiver: ? 150 mA (without outputs)
Time delay before availabilitysee Table 1, max. 3.8 s

Interface

Interface typeIO-Link ( pin 4 )
IO-Link Revision1.0
COM-ModeCOM2 (38.4 kBaud)
Min. cycle time2.3 ms
Process data witdh16 bit
SIO mode supportyes
Device ID1050369 ... 1050389 ( 0x100701 ... 0x100715 )

Input

Test inputEmitter switch-off with +UB or 0V at pin 4 (emitter)
Function inputRange input activation from 1.6 m with +UB or 0 V on pin 2 (emitter)
Teach-In input for parameterization on pin 8 (receiver)

Output

Pre-fault indication outputStability Control (SC) 1 PNP, short-circuit protected, reverse polarity protected on pin 2 (receiver)
Switching typeFactory setting: dark on , Switchable to light-on mode
Signal outputCommand interface: Pin 4 IO-Link interface C or used as switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver)
Switch output: Pin 5 switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) synchronized with pin 4
Switching thresholdFactory setting: The signal tracking for the threshold value is deactivated, increasing the optical resolution by a maximum of 4mm; switchable to active signal tracking
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA
Voltage drop